Heating Element (PTC) 3 -Z132-, Removing And Installing: Installing
Install in the reverse order of removal while noting the following:
Conditions
- The contact surfaces must be clean.
-- Clean dirty attachment points for the potential equalization cable. Refer to the appropriate service information .
-- Connect the potential equalization cable -2- and tighten the nut -3-.
-- Attach the connectors -4- and -6-.
Fill the cooling system using the Cooling System Service Machine - TEXA :VAS 531 011 .
-- Refer to COOLING SYSTEM, FILLING .
Fill the cooling system using the Cooling System Charge Kit :VAS 6096 .
-- Refer to COOLING SYSTEM, FILLING .
Continuation for all vehicles
There is a risk of fatal injury due to high voltage.
Electrocution by direct contact or electric arc can cause severe bodily injury or fatal injury.
- Have a high-voltage technician or a high-voltage expert bring the high-voltage system back into service.
-- Refer to [For engine(s) EBRA] High-Voltage System, Re-Energizing .