Flat Connector Systems
If necessary, housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing the contacts. Refer to SECONDARY LOCK .
Flat Connector System with One Retaining Tab:
-- Guide the release tool which fits the contact housing into release channel on contact housing.
-- Grasp contact at wire and push it gently into contact housing -arrow-.
By pushing the contact in the direction of the contact housing, the contact retaining tab is lifted off the housing shoulder and can be released using the release tool.
-- At the same time, push release tool in direction of contact housing and pull the released contact out of contact housing -arrow-.
-- After removing the contact, release tool can be pulled out of the contact housing again.
Flat Connector System with Two Retaining Tabs:
-- Guide the release tool which fits the contact housing into release channel on contact housing.
-- Grasp contact at wire and push it gently into contact housing until it stops -arrow-.
By pushing the contact in the direction of the contact housing, the contact retaining tabs are lifted off the housing shoulder and can be released using the release tool.
-- At the same time, push release tool in direction of contact housing and pull the released contact out of contact housing -arrow-.
-- After removing the contact, release tool can be pulled out of the contact housing again.
Asymmetrical:
-- Guide the release tool which fits the contact housing into release channel on contact housing.
-- Grasp contact at wire and push it gently into contact housing -arrow-.
By pushing the contact in the direction of the contact housing, the contact retaining tabs are lifted off the housing shoulder and can be released using the release tool.
-- At the same time, push release tool in direction of contact housing and pull the released contact out of contact housing -arrow-.
-- After removing the contact, release tool can be pulled out of the contact housing again.