Refrigerant Circuit Pressure Sensor -G805-, REMOVING AND INSTALLING: Removing
Danger or frostbite due to refrigerant coming out under pressure. If work is performed improperly the connection can tear and refrigerant can flow out.
Frostbite on the skin and other parts of the body is possible.
- Wear safety gloves.
- Wear protective eyewear.
- Counterhold the refrigerant line with a suitable tool.
-- Disconnect the connector -2-.
-- Counterhold the refrigerant line with a suitable tool. Loosen the Refrigerant Circuit Pressure Sensor -G805- -1- with the :T40284 while doing so.
Danger or frostbite due to refrigerant coming out under pressure.
Frostbite on the skin and other parts of the body is possible.
- Wear safety gloves.
- Wear protective eyewear.
- If refrigerant flows out of the refrigerant line longer than 1 second when loosening the pressure sensor, tighten the pressure sensor and replace the faulty check valve.
- Extract refrigerant and open the refrigerant circuit immediately.
- If more than 10 minutes elapse after extracting the refrigerant and the refrigerant circuit was not opened, extract the refrigerant again. Pressure can develop in the refrigerant circuit due to evaporation.
-- For all the following work, close the open lines and connections with clean plugs from the :VAS6122 .
-- Remove the Refrigerant Circuit Pressure Sensor -G805- -1-.