Home >> Volkswagen >> 2023 >> ID.4 S >> Repair and Diagnosis >> External Pages >> Different car >> Section 12 (Air Conditioning Refrigerant R1234YF Servicing (2 Of 2)) >> 87 Air Conditioning >> Working With A/C Service Station >> Contaminated Refrigerant, Filling In Recycling Cylinder For Analysis, Processing, Or Disposal >> RECYCLING CYLINDER, FILLING WITH CONTAMINATED REFRIGERANT USING Extractor:VAS581007

RECYCLING CYLINDER, FILLING WITH CONTAMINATED REFRIGERANT USING Extractor:VAS581007

WARNING: This page is about a different car, the 2022 Volkswagen ID.4 and 2021 Volkswagen ID.4. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

CAUTION:

Risk of frostbite or suffocation due to dry ice.

Frostbite of the skin and other body and suffocation as a gas is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Only work with the dry ice in well-ventilated areas.

- Never work near basement staircases or other low-lying areas.

CAUTION:

Risk of explosion due to improperly stored dry ice.

When dry ice evaporates the pressure in the container increases. Unsuitable containers can explode.

- Transport and store dry ice only in the containers designed for it.

Fill the Refrigerant in a Supercooled Recycling Cylinder.

-- Remove the recycling cylinder seal and remove the closure cap from the connection.

-- Connect the A/C Service Station to the recycling cylinder. To do so remove the low pressure service coupling from the A/C Service Station filler hose and connect the filler hose directly with the adapter belonging to the Extractor :VAS581007  to the adapter on the recycling cylinder.

-- Carefully open the recycling cylinder hand shut-off valve to check the vacuum and check the vacuum in the cylinder.

-- If necessary evacuate the recycling cylinder using the A/C Service Station.

-- Close the recycling cylinder hand shut-off valves.

-- Switch off the ignition.

-- For good ventilation of the work space switch on the workshop ventilation equipment if equipped.

CAUTION:

There is a risk of explosion due to overfilling refrigerant cylinders.

Refrigerant can expand and the refrigerant cylinder can explode due to overfilling.

- Use a refrigerant cylinder with a safety valve.

- Never exceed the permitted capacity of the refrigerant cylinder.

CAUTION:

Chemical reaction due to contaminated refrigerant. When mixing gases of unknown composition different chemical reactions can occur.

Injury is possible.

- Never mix refrigerant of different origins.

-- Connect the service coupling for refrigerant R1234yf -5- to the filler hose -4-.

GWWA87-12270Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Connect the filler hose -4- with the connection piece -3- (and seal -2-) on the recycling cylinder -1-.

-- Position the spacer -6- in the insulated container -7-.

-- Cover the bottom of the insulated container -7- with dry ice.

-- Position the recycling cylinder -1- in the insulated container -7-.

-- Fill the remaining dry ice in the insulated container -7-.

-- Cool the recycling cylinder -1- with dry ice (approximately 15 minutes).

-- Connect the recycling cylinder -1- via the service coupling -5- on the vehicle refrigerant circuit.

-- Open the recycling cylinder hand shut-off valve -1-.

-- Connect the pressure gauge to the refrigerant circuit (or the use the A/C Service Station pressure gauge) and check the refrigerant circuit pressure.

-- Carefully open the service coupling -5- on the filler hose to the recycling cylinder and let the refrigerant flow slowly in the recycling cylinder -1-.

-- Wait until the refrigerant in the recycling cylinder -1- is liquid (pay attention to the pressure indicator on the connected pressure gauge).

-- Close the service coupling -5- and the recycling cylinder hand shut-off valve -1-.

-- Remove the filler hose -4- and connection piece -3- from the recycling cylinder -1- and close the recycling cylinder connection with the closure cap.

-- Place the insulated container -7- with the recycling cylinder -1- and the dry ice in a secured, well ventilated area outside of the building.

-- Open the cover of the insulated container -7- or remove and let the dry ice completely evaporate.

CAUTION:

Risk of damaging the recycling container due to impact.

- Remove the recycling bottle first from the insulated container, when the dry ice is evaporated and the recycling bottle has taken the ambient temperature.

NOTE:

Remove the recycling bottle -1- first from the insulated container -7-, when the dry ice is evaporated and the recycling bottle has taken the ambient temperature.

-- Remove the recycling cylinder -1- from the insulated container -7-.

-- Place the recycling bottle -1- at a suitable location until picked up by the gas preparator / gas disposer.

-- Evacuate the refrigerant circuit with the A/C Service Station for at least one hour. Refer to REFRIGERANT CIRCUIT, EVACUATING .

-- Fill out the supplement data sheet for the recycling cylinder with contaminated refrigerant and secure on the recycling cylinder.

-- Return the filled recycling cylinder using the method of delivery for the recycling cylinder, while paying attention to the applicable laws.