RECYCLING CYLINDER, FILLING WITH CONTAMINATED REFRIGERANT USING Extraction Unit:VAS581011
WARNING: This page is about a different car, the 2022 Volkswagen ID.4 and 2021 Volkswagen ID.4. However, it is still accessible from the selected car via links, so may be relevant.
Special tools and workshop equipment required
- Extraction Unit :VAS581011
- A/C Service Station R1234yf :VAS581003 or another VASA/C Service Station R1234yf
- Evacuated recycling container for contaminated R1234yf, commercially available from the gas supplier
Procedure
-- Connect the Extraction Unit :VAS581011 according to the included Owner's Manual with the vehicle and the A/C Service Station R1234yf :VAS581003 .
-- Fill the contaminated refrigerant using the Extraction Unit :VAS581011 in the recycling cylinder. Refer to the Owner's Manual.
-- Fill out the supplement data sheet for the recycling cylinder with contaminated refrigerant and secure on the recycling cylinder.
-- Return the filled recycling cylinder using the method of delivery for the recycling cylinder, while paying attention to the applicable laws.
-- Evacuate the refrigerant circuit with the A/C Service Station for at least one hour. Refer to REFRIGERANT CIRCUIT, EVACUATING .
- Then by evacuating the rest of the contaminated refrigerant, which could be attached to the refrigerant oil can be removed at an absolute pressure of less than 10 mbar (0.15 psi).