Cooling System Charge Kit - Electric Vacuum Pump :VAS6096/2, CHECKING
Special Tools And Workshop Equipment Required
- Cooling System Charge Kit :VAS6096
- Cooling System Charge Kit - Electric Vacuum Pump :VAS6096/2
Before using the :VAS6096 and the :VAS6096/2 , a check must be performed to ensure that the cooling system is filled correctly.
-- Connect the hose -1- of the :VAS6096/2 to the connector coupling -B- on the :VAS6096 .
-- Connect the :VAS6096/2 on the vehicle battery and switch on.
-- Close valve -A- and open valve -B-.
-- The needle on the pressure gauge -arrow- must move until it is well below the green area.
-- Close the valve -B- and switch off the :VAS6096/2 .
-- Monitor the vacuum on the pressure gauge for 10 seconds. The needle must not move.
If Not Enough Vacuum Builds Up, Or The Pressure Continues To Increase:
The :VAS6096 , the pressure gauge or the :VAS6096/2 is leaking or faulty and must not be used.