Reducing Agent Delivery Module, Removing And Installing: Removing
-- Drain the reducing agent tank. Refer to REDUCING AGENT TANK, DRAINING .
-- Remove the reducing agent tank. Refer to REDUCING AGENT TANK, REMOVING AND INSTALLING .
-- Place the reducing agent tank on a clean surface.
-- While doing so, the delivery module must face upward.
-- Clean the area around the delivery module -5-.
-- Disconnect the connectors -1 and 3-.
-- Disconnect the reducing agent delivery line -2-. Refer to REDUCING AGENT DELIVERY LINE, DISCONNECTING .
-- To catch escaping reducing agent place a clean cloth under the separation point.
-- Seal all the open lines and connections with clean plugs from the :VAS6122 .
-- Remove the bolts -arrows-.
-- Carefully pry out the delivery module -5- from the opening -4- with a screwdriver.
-- Remove the delivery module from the reducing agent tank.