Camshaft, Measuring Axial Clearance
Special tools and workshop equipment required
- Dial Gauge Holder: VW387
- Dial Gauge - 0-10mm: VAS6079
Procedure
-- Remove the camshaft housing. Refer to CAMSHAFT HOUSING, REMOVING AND INSTALLING .
-- Secure the : VAS6079 on the camshaft housing with the : VW387 as shown.
-- Press the camshaft against the dial gauge by hand.
-- Set the dial gauge to "0".
-- Push the camshaft off the dial gauge and read the value.
Axial clearance:
- Wear limit: 0.25 mm.