Charge Air System, Checking For Leaks
Special tools and workshop equipment required
- Turbo System Tester Kit: VAG1687
- Engine Bung Set: VAS6122
Procedure
-- Loosen the hose clamps -1 and 2- and remove the air duct pipe.
-- Remove the vent pipe for the crankcase ventilation -arrow-.
-- Close the connections with a plug -1- from the : VAS6122 and secure using a hose clamp -2-.
-- Connect the : VAG1687/10 with the : VAG1687/14 to the turbocharger.
-- Connect the : VAG1687 to the adapter.
Prepare the : VAG1687 as Follows:
-- Pull the pressure regulating valve -2- upward and remove completely, close the valves -3 and 4-.
-- Connect the : VAG1687 to compressed air -1- with a commercially available intermediate piece.
If there is water in the viewing glass -6-, drain it through the drain plug.
-- Open the valve -3-.
-- Set the pressure to 0.5 bar (7.2 psi) using the pressure regulating valve -2-.
-- Open the valve -4- and wait until the test circuit is filled. Regulate the pressure to 0.5 bar (7.2 psi) again if necessary.
-- Inspect the charge air system for poorly sealed areas by listening, feeling, using commercially available leak detection spray or by using the : VAG1842S .
A small quantity of air dissipates via the valves in the engine. For this reason a pressure retention test is not possible.
Information on the : VAG1842S . Refer to the Operating Instructions.
Release the pressure in the test circuit by pulling off the hose coupling before removing the adapter.
Assembling
Assembly is performed in reverse order.