LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 2018 >> Beetle S, 2D Hatchback >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 6 (General, Technical Data (Refrigerant R134A General Information) (Convertible)) >> 00 General, Technical Data >> Refrigerant Circuit General Information >> Refrigerant Circuit Extraction And Filling Valves For Service Station Couplings >> Evacuating And Charging Valve, High Pressure Side

Evacuating And Charging Valve, High Pressure Side

WARNING: This page is about a different variant/trim than selected.

Special tools and workshop equipment required 

WARNING:

There is a danger of ice-up.

Refrigerant will leak out if refrigerant circuit is not discharged.

Refrigerant must be extracted before opening refrigerant circuit. If refrigerant circuit is not opened within 10 minutes of extraction, pressure may form in refrigerant circuit due to evaporation. Extract the refrigerant once more.

Allocation in vehicle.

Refer to COMPONENT LOCATION OVERVIEW - A/C SYSTEM for the vehicle-specific Service Information.

Fig 1: Exploded View Of Connection With High-Pressure Valve
GWWV87-1435Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
NOTE:

Torque Wrench 1783 - 2-10Nm :VAG1783  with Torque Wrench 1783 - 1/4" Drive Ratchet :VAS6234 

Use a suitable Refrigerant Sockets :T10364  to loosen the valve insert. Refer to Figure

  1. Socket with external or internal threads
  2. Seal identification: black or colored
  3. Valve with external thread and groove for seal (7 Nm)
  4. Seal identification: black or colored
  5. Cap