LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 2018 >> Beetle S, 2D Hatchback >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 6 (General, Technical Data (Refrigerant R134A General Information) (Convertible)) >> 00 General, Technical Data >> Refrigerant Circuit General Information >> Pressure Gauge, Tests And Measurements >> Pressure Gauge Uses

Pressure Gauge Uses

WARNING: This page is about a different variant/trim than selected.

a - Pressure and Temperature Measurement at Refrigerant Circuit

NOTE:

The relationship between pressure and temperature indicated on the gauges only exists in a refrigerant circuit that contains liquid or vapor, but not gas. In a gaseous state, the temperature is approximately 10 °C (50 °F) to 30 °C (86 °F) higher than indicated on the gauge.

b - Verification of Refrigerant in a Closed Container

Refrigerant R134a is present in a closed vessel or in a refrigerant circuit when the temperature indicator on the gauge matches the refrigerant temperature (the temperature of standing fluid is equal to the outside temperature).

A closed vessel or a refrigerant circuit that has been switched off is empty when the temperature indicated on the gauge is below the temperature of the refrigerant.

NOTE:

The relationship between pressure and temperature indicated on the gauges no longer applies if no liquid is present and the pressure is built up solely by gas.