Fill UV-leak detective additive (UV-leak detective additive may not be used for ID.3) using the in the refrigerant circuit.
-- Add the UV-leak detection additive (UV-leak detective additive may not be used for ID.3) and the specified refrigerant quantity into the refrigerant circuit using the A/C Service Station. Refer to REFRIGERANT CIRCUIT, CHARGING and TECHNICAL DATA .
The quantity of UV leak detection additive (UV-leak detective additive may not be used for ID.3) which is filled on a refrigerant circuit with a refrigerant oil quantity up to 150 cm3 is 3.0 ± 0.5 ml. If the refrigerant oil capacity in the refrigerant circuit is larger, then more UV leak detection additive (UV-leak detective additive may not be used for ID.3) must be added accordingly (for example, 5.0 ± 0.5 ml for a refrigerant circuit with a refrigerant oil capacity of 250 cm 3 . When filling the UV leak detection additive using an A/C Service Station the set quantity in the A/C Service Station can vary for this reason pay attention to the corresponding Owner's Manual. Refer to A/C Service Station Owner's Manual.
The actual refrigerant oil quantity in the refrigerant circuit can be found in the vehicle-specific service information. Refer to TECHNICAL DATA .
If UV leak detection additive was filled already in a refrigerant circuit for an earlier repair, note the following: only add new UV leak detection additive (UV-leak detective additive may not be used for ID.3) if the refrigerant oil will be replaced. If only a portion of the refrigerant oil was replaced, only add a proportionate amount of the UV leak detection additive. For example, if 50 ml of refrigerant oil was replaced in a vehicle with 150 ml, add only 1.0 ml (cm3 ) of UV leak detection additive.
The Leak Detection System has the following components:
- Cleaning Solution -3-
- UV Leak Detection Lamp -4-
- Protective Eyewear -5-
- Sticker -6-
- Safety Gloves -8-
Ignore items -1, 2, and 7- in the image.
Special tools and workshop equipment required
- Leak Detection System
- A/C Service Station with the ability to add UV leak detection additive (UV-leak detective additive may not be used for ID.3) in the refrigerant circuit. Refer to the service information.
- Approved leak detection additive. Refer to the service information.
-- Evacuate the refrigerant circuit according to the procedure and fill with UV leak detection additive (UV-leak detective additive may not be used for ID.3) and refrigerant. Refer to REFRIGERANT CIRCUIT, EVACUATING and REFRIGERANT CIRCUIT, CHARGING .
-- Wait until the pressure in the high and low pressure side have equalized.
-- Disconnect the A/C Service Station from the refrigerant circuit and turn it off. Refer to A/C SERVICE STATION, SWITCHING OFF AND DISCONNECTING FROM REFRIGERANT CIRCUIT .
-- Fill in the label near the service connection stating that UV-leak detection additive (UV-leak detective additive may not be used for ID.3) was added to the refrigerant circuit.
-- Remove the residual UV-leak detection additive for example with absorbent paper from the service connection and the surrounding area and clean using Leak Detection Kit - Cleaning Solution -VAS6201/3-.
-- Seal the service connection with the cap.
-- Start the A/C system.
-- Operate the A/C system for at least 60 minutes with the A/C compressor switched on.
-- Check for leaks on the refrigerant circuit using UV Lamp. Refer to Check for Leaks on the Refrigerant Circuit Using. .