Home >> Volkswagen >> 2018 >> Beetle S, 2D Hatchback >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 53 (Air Conditioning (Refrigerant R1234YF Servicing) (2 Of 2) (Convertible)) >> 87 Air Conditioning >> Refrigerant Circuit >> General Description - Refrigerant Circuit Components >> Check Valve

Check Valve

WARNING: This page is about a different variant/trim than selected.

The check valves disconnect in different areas of the refrigerant circuit. Refer to REFRIGERANT CIRCUIT (vehicle-specific service information).

Fig 1: Exploded View Of Check Valve
GWWA87-12180Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
NOTE:

The illustrated check valve -3- is installed for example on a Audi Q7 e-tron. Refer to REFRIGERANT CIRCUIT (vehicle-specific service information).

The check valves in the refrigerant circuit in the flow direction have a specified residual pressure (approximately 0.1 bar (1.45 psi) or 100 mbar (1.45 psi)). So that the refrigerant circuit can be completely evacuated (residual pressure less than 5 mbar (0.073 psi)), all electrically activated valves must be opened.

Depending on the version the flow direction can be marked using a sticker.