Round Connector Systems
The equipped housing securing mechanisms (secondary locks) must be released or removed using the specified tool before releasing the contacts. Refer to SECONDARY LOCK .
-- Guide the corresponding connector housing release tool into the release channel on the connector housing.
-- Grip the contact at the wire and gently push it into the connector housing -arrow-.
By pushing the contact in the direction of the connector housing, contact retaining tabs are lifted off the housing shoulder and can be released using the release tool.
-- At the same time, push the release tool in the direction of the connector housing and pull the released contact out of the connector housing.
After removing the contact, release tool can be pulled out of the connector housing again.