Checking the Vent Lines and EVAP Canister
-- Remove the bleed line -1-. Disconnect the connector couplings. Refer to CONNECTOR COUPLINGS, SEPARATING .
-- Connect the Hand Vacuum Pump VAS 6213 to the vent line to the EVAP canister as illustrated.
-- Secure the Pressure Tester Kit - Adapter Set - Fitting VAS 6550/3-1 on the vent line.
-- Connect the Hand Vacuum Pump VAS 6213 and the Pressure Tester Kit - Adapter Set - Fitting VAS 6550/3-1 using a standard hose -A-.
-- Set the slide ring -1- on the Vacuum Pump VAS 6213 in position -A- for "vacuum".
-- Operate the Hand Vacuum Pump VAS 6213 several times. No vacuum should be built up.
If A Vacuum Forms
-- Check the vent line at the EVAP canister for contamination and clean if necessary -Item 9- in Figure.
If No Vacuum Forms
-- Seal the breather hole -arrow- closed and operate the vacuum pump several times again. A vacuum must form.
If No Vacuum Forms
-- Clamp off the hose between the EVAP canister -1- and EVAP Canister Purge Regulator Valve 1 -N80- -5-.
-- Actuate the vacuum pump again a few times.
If A Vacuum Forms
The EVAP canister and the line -3- are OK.
If No Vacuum Forms
-- Check the EVAP canister for leaks and damage and replace if necessary.
-- Check the line to the EVAP Canister Purge Regulator Valve 1 -N80- for leaks and damage.
If No Malfunction Can Be Found
Check the wire to the separating point on the underbody.
-- Release and remove the vent line -1-. Disconnect the connector couplings. Refer to CONNECTOR COUPLINGS, SEPARATING .
-- Seal the vent line -1- with the Sealing Tool T10249.
-- Connect the Hand Vacuum Pump VAS 6213 with the Pressure Tester Kit - Adapter Set - Hose 2 VAS 6550/3-2 to the line to the fuel tank.
-- Operate the vacuum pump several times. A vacuum must form.
If No Vacuum Forms
-- Check the line to the fuel tank for leaks and damage.
If No Malfunction Can Be Found
-- Check the fuel tank for leaks and damage.