Charge Air System, Checking For Leaks: Procedure
-- Remove the noise insulation. Refer to NOISE INSULATION .
-- Release the clamp -A- and remove the hose -B- from the charge air pipe.
-- Attach the -A- :VAG1687/5 to the charge air hose.
-- Turn the -B- :VAG1687/5 clockwise approximately 90° in direction of -arrow-.
-- Attach the :VAG1687 as illustrated below.
Prepare the :VAG1687 as Follows:
-- Pull the pressure regulating valve -2- upward and remove completely, close the valves -3 and 4-.
-- Connect the :VAG1687 to compressed air -1- with a commercially available intermediate piece.
If there is water in the viewing glass -6-, drain it through the drain plug.
-- Open the valve -3-.
-- Set the pressure to 0.5 bar (7.2 psi) using the pressure regulating valve -2-.
-- Open the valve -4- and wait until the test circuit is filled. Regulate the pressure to 0.5 bar (7.2 psi) again if necessary.
-- Inspect the charge air system for poorly sealed areas by listening, feeling, using commercially available leak detection spray or by using the :VAG1842S .
A small quantity of air dissipates via the valves in the engine. For this reason a pressure retention test is not possible.
Refer to the Owner's Manual for information on using the :VAG1842S .
Release the pressure in the test circuit by pulling off the hose coupling before removing the adapter.