Monitor-ID $A2: Misfire Cylinder 1 Data
-- CONNECT: Scan Tool
-- START ENGINE: Idle
-- SELECT: Mode 06
-- SELECT: "Monitor-ID $A2"
-- SELECT: "Test-ID".
-- CHECK: values listed below at idle.
| Test-ID | DTC | Component or System | Min. | Max. | Additional Information |
|---|---|---|---|---|---|
| $0B | P0301 | Average value over 10 DCYs | 0.0 cnts | 65, 535.0 cnts | Refer to DTC P0301 Engine Control Module --, 2015 MY => P0301 in the DTC summary table. |
| $0C | P0301 | Combustion misfires in this DCY | 0.0 cnts | 65, 535.0 cnts | Refer to DTC P0301 Engine Control Module --, 2015 MY => P0301 in the DTC summary table. |
-- If any of components or systems fail to meet the specified values. Refer to Diagnostic "Mode 03: Interrogating Fault Memory" to check for stored DTC's or the corresponding diagnostic repair procedure DIAGNOSTIC MODE 03 - READ DTC MEMORY .
-- Switch the ignition OFF.