Home >> Volkswagen >> 2017 >> Golf S, Eng CD CXBA, Standard Trans >> Repair and Diagnosis >> Engine Mechanical >> Blowers, Superchargers & Turbochargers >> Turbocharger System (Service Information - CXBA, CNSA, CXBB, CNSB, CXCA, CXCB) >> 21 Turbocharger, Supercharger >> Charge Air System >> Charge Air System, Checking For Leaks >> Procedure

Charge Air System, Checking For Leaks: Procedure

-- Loosen the hose clamps -1 and 2- and remove the air guide pipe.

GWWA21-10818Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Connect the :VAG1687/10  with the :VAG1687/14  to the turbocharger.

GWWA21-10819Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Connect the :VAG1687  to the adapter.

Prepare the :VAG1687  as follows:

GWWV21-0168Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Pull the pressure regulating valve -2- upward and remove completely, close the valves -3 and 4-.

-- Connect the :VAG1687  to compressed air -1- with a commercially available adapter piece.

NOTE:

If there is water in the viewing glass, it must be drained through the drain plug -6-.

Pressure must not exceed 0.5 bar (7.2 psi)!

-- Open the valve -3-.

-- Set the pressure to 0.5 bar (7.2 psi) using the pressure control valve -2-.

-- Open the valve -4- and wait until the test circuit is filled. Regulate the pressure to 0.5 bar (7.2 psi) again if necessary.

-- Listen, feel and use commercially available leak detection spray or the :VAG1842S  to check the charge air system for leaks.

NOTE:

A small quantity of air dissipates via valves in engine. A pressure retention test is not possible for this reason.

Information on the :VAG1842S  . Refer to the Operating Instructions.

Release the pressure in the test circuit by pulling off the hose coupling before removing the adapter.