Home >> Volkswagen >> 2017 >> Golf R Standard Trans >> Repair and Diagnosis >> Engine Mechanical >> Cooling System (Mechanical) >> COOLING SYSTEM [4-Cylinder Direct Injection (2.0L, 4V, Turbocharger, Chain Drive, Generation III)] >> 19 Cooling System >> Coolant Pump/Thermostat >> Coolant Shut-Off Valve -N82-, Removing And Installing >> Removing

Coolant Shut-Off Valve -N82-, Removing And Installing: Removing

-- Remove the air filter housing. Refer to AIR FILTER HOUSING, REMOVING AND INSTALLING .

-- Loosen the hose clamp -2-.

GWWA21-10813Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Remove bolt -1-, push the left air guide pipe left.

-- Disconnect the connector -2-.

-- Clamp the coolant hoses on Coolant Shut-Off Valve -N82- with the :3094  .

NOTE:

Place a cleaning cloth underneath, to catch coolant leaking out.

-- Loosen the hose clamps -1- and remove the coolant hoses.

-- Remove the bolts -arrows-, and remove the Coolant Shut-Off Valve -N82-.

Fig 1: Installed Location Coolant Shut-Off Valve -N82-
GWWA19-11619Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.