LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 2016 >> e-Golf SE >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> Solar Ventilation >> Air Conditioning (Refrigerant R1234YF Servicing) (2 Of 2) >> 87 Air Conditioning >> Working With A/C Service Station >> Contaminated Refrigerant, Filling In Recycling Container For Analysis, Processing, Or Disposal >> RECYCLING CONTAINER, FILLING WITH CONTAMINATED REFRIGERANT USING Extractor :VAS581007

RECYCLING CONTAINER, FILLING WITH CONTAMINATED REFRIGERANT USING Extractor :VAS581007

Special tools and workshop equipment required 

CAUTION:

Risk of frostbite or suffocation due to dry ice. 

Frostbite of the skin and other body and suffocation as a gas is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Only work with the dry ice in well-ventilated areas.

- Never perform procedures in and near basement staircases or other below ground areas.

CAUTION:

Risk of explosion due to improperly stored dry ice. 

When dry ice evaporates the pressure in the container increases. Unsuitable containers can explode.

- Transport and store dry ice only in the containers designed for it.

Fill the Refrigerant in a Supercooled Recycling Bottle. 

-- Remove the recycling bottle seal and remove the closure cap from the connection.

-- Connect the A/C Service Station to the recycling container. To do so remove the low pressure service coupling from the A/C Service Station filler hose and connect the filler hose directly with the adapter belonging to the Extractor:VAS581007  to the adapter on the recycling bottle.

-- Carefully open the recycling bottle hand shut-off valve to check the vacuum and check the vacuum in the bottle.

-- If necessary evacuate the recycling bottle using the A/C Service Station.

-- Close the recycling bottle hand shut-off valves.

-- Switch off the ignition.

-- For good ventilation of the work space switch on the workshop ventilation equipment if equipped.

CAUTION:

There is a risk of explosion due to overfilling refrigerant canisters.

Refrigerant can expand and the refrigerant canister can explode due to overfilling.

- Use a refrigerant canister with safety valve.

- Never exceed the permitted capacity of the refrigerant canister.

CAUTION:

Chemical reaction due to contaminated refrigerant. When mixing gases of unknown composition different chemical reactions can occur.

Injury is possible. 

- Never mix refrigerant of different origins.

-- Connect the service coupling for refrigerant R1234yf -5-  to the filler hose -4-  .

GWWA87-12270Courtesy of AUDI OF AMERICA, LLC

-- Connect the filler hose -4-  with the connection piece -3-  (and seal -2-  ) on the recycling bottle -1-  .

-- Position the spacer -6-  in the insulated container -7-  .

-- Cover the bottom of the insulated container -7-  with dry ice.

-- Position the recycling bottle -1-  in the insulated container -7-  .

-- Fill the remaining dry ice in the insulated container -7-  .

-- Cool the recycling bottle -1-  with dry ice (approximately 15 minutes).

-- Connect the recycling container -1-  via the service coupling -5-  on the vehicle refrigerant circuit.

-- Open the recycling bottle hand shut-off valve -1-  .

-- Connect the pressure gauge to the refrigerant circuit (or the use the A/C Service Station pressure gauge) and check the refrigerant circuit pressure.

-- Carefully open the service coupling -5-  on the filler hose to the recycling bottle and let the refrigerant flow slowly in the recycling bottle -1-  .

-- Wait until the refrigerant in the recycling bottle -1-  is liquid (pay attention to the pressure indicator on the connected pressure gauge).

-- Close the service coupling -5-  and the recycling bottle hand shut-off valve -1-  .

-- Remove the filler hose -4-  and connection piece -3-  from the recycling bottle -1-  and close the recycling bottle connection with the closure cap.

-- Place the insulated container -7-  with the recycling bottle -1-  and the dry ice in a secured, well ventilated area outside of the building.

-- Open the cover of the insulated container -7-  or remove and let the dry ice completely evaporate.

CAUTION:

- Remove the recycling bottle first from the insulated container, when the dry ice is evaporated and the recycling bottle has taken the ambient temperature.

-- Remove the recycling bottle -1-  from the insulated container -7-  .

-- Evacuate the refrigerant circuit with the A/C Service Station for at least one hour. Refer to REFRIGERANT CIRCUIT, EVACUATING .

-- Fill out the supplement data sheet for the recycling bottle with contaminated refrigerant and secure on the recycling bottle.

-- Return the filled recycling bottle using the method of delivery for the recycling bottle, while paying attention to the applicable laws.