LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 2016 >> e-Golf SE >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> Solar Ventilation >> Air Conditioning (Refrigerant R1234YF Servicing) (1 Of 2) >> 87 Air Conditioning >> Refrigerant Circuit >> Leaks, Finding >> Refrigerant Circuit, Finding Leaks Using Electronic Leak Detector >> Perform a Leak Detection Test on a Refrigerant Circuit That Is Filled with Refrigerant:

Perform a Leak Detection Test on a Refrigerant Circuit That Is Filled with Refrigerant:

-- Switch off the ignition.

-- Start up the leak detector in line with relevant operating instructions.

-- Always hold the test probe underneath the suspected leak.

Fig 1: A/C Refrigerant System, Checking For Leaks
GWWV87-1455Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

Depending on the model, leak detection is indicated by an increase in clicking rate or a warning tone. Refer to the Leak Detection Device Owner's Manual.

NOTE:

Currents of air quickly disperse refrigerant gas. Drafts must therefore be avoided during leak detection.

Refrigerant gas is heavier than air and will escape.