Determining the Shim
WARNING: This page is about a different variant/trim than selected.
The required bearing tension is reached as follows:
The specified bearing pre-load is reached when determined measured value (0.14 mm) is subtracted from inserted adjustment shim (1.70 mm).
A constant figure of (0.20 mm) is added to the reading.
Example:
| Inserted shim | 1.70 mm |
| - measured value | 0.14 mm |
| + Preload (constant value) | 0.20 mm |
| Shim thickness | 1.76 mm |
-- Select the correct shim thickness according to the table. Refer to Shim Table .
-- Remove the transmission housing and remove the tapered roller bearing outer race from the transmission housing.
A - Counter Support, for example, Puller - Kukko Counterstay :Kukko 22/2 .
B - Internal Puller 46 to 58 mm, for example, Puller - Kukko Internal - 46-56mm :Kukko 21/7 .
-- Remove the inserted shim (1.70 mm) from the transmission housing.