Pump Injector Unit O-Ring
Special tools and workshop equipment required
- Assembly sleeve T10056
Removing
-- Remove the pump injector unit, refer to PUMP INJECTOR UNIT .
-- Pry off old O-rings from pump injector unit extremely carefully.
-- Above all, make sure that no burrs develop at O-ring seat.
Installing
Always use assembly sleeves for installing O-rings. Not using them may cause the O-rings to be damaged during installation.
O-rings without distinguishing color markings are gradually introduced. Ensure the correct allocation of O-rings to grooves: ring strength decreases in direction toward injector.
Avoid rolling movements when sliding on O-rings. O-rings must not be twisted on itself in the seat of Pump-Injector Unit.
-- Pull off heat protection seal together with securing ring.
-- Clean seating surfaces for O-rings on pump injector unit very carefully.
-- Insert assembly sleeve T10056/1 up to stop on pump injector unit.
-- Slide the upper, thicker O-ring carefully on assembly sleeve and into seat of pump injector unit.
-- Remove assembly sleeve.
-- Insert assembly sleeve T10056/2 up to stop on pump injector unit.
-- Slide the center, thinner O-ring carefully on assembly sleeve and into seat of pump injector unit.
-- Remove assembly sleeve.
-- Insert assembly sleeve T10056/3 up to stop on pump injector unit.
-- Slide the lower O-ring carefully on assembly sleeve and into seat of pump injector unit.
-- Remove assembly sleeve.
-- Slide on a new heat protection seal together with securing ring.