Turbocharger Vacuum Diaphragm, Adjusting
Special Tools And Workshop Equipment Required
- Dial gauge holder VW 387
- Hand vacuum pump VAS 6213
- Pressure control valve VAS 6342
- Turbocharger tester VAG 1397A
- Dial gauge (0-30 mm) VAS 6341/1
- Dial gauge extension (30 mm) VAS 6341/3
- Flat pickup VAS 6341/4
The vacuum diaphragm must be adjusted only if the linkage was loosened.
Adjustment is performed only with turbocharger removed.
-- Disconnect the hose -arrow- from the vacuum diaphragm.
-- Loosen the clip above the linkage.
-- Loosen the lock nut -2-.
-- Pre-adjust the bypass flap -1- above the linkage for the vacuum diaphragm -arrow- so that the bypass flap can still just be turned by hand.
-- Tighten the lock nut by hand.
-- Connect the VAS 6213, VAG 1397A to connection II and the VAS 6342 as shown in the illustration.
-- Close the VAS 6342 at the lever -1-.
-- Set the slide ring -1- on the VAS 6213 to position -B- for "pressure".
-- Switch on the VAG 1397A and set the slider switch to position II.
-- Secure the VW 387 on turbocharger -arrow-.
-- Secure the VAS 6341/1 with the VAS 6341/3 and the VAS 6341/4 onto the VW 387.
-- Set the VAS 6341/1 to 0 bar with 1 mm preload.
-- Rotate the indicator on the VAS 6341/1 to 0.
-- Check the dial indicator for ease of movement.
-- Operate the VAS 6213 until the VAG 1397A displays 350 ± 5 mbar.
-- The VAS 6341/1 must display 4.1 mm to 4.3 mm, otherwise rotate the vacuum diaphragm linkage until the value is displayed.
-- Tighten the lock nut by hand.
-- Repeat the measurement.
The mm specifications apply to the value read out (includes 1 mm preload).
-- Release the pressure via the VAS 6342 to 0 mbar.
-- Set the VAS 6341/1 to 0.
The following measurements must be performed in one sequence. In the meantime, pressure must not dissipate to 0.
-- Operate the VAS 6213 until the VAG 1397A displays 350 ± 5 mbar.
-- Read and make a note of the value on the VAS 6341/1.
-- Operate the VAS 6213 until the VAG 1397A displays 650 to 700 mbar.
-- Release the pressure via the VAS 6342 to 350 ± 5 mbar.
-- Read and make a note of the value on the VAS 6341/1.
-- Add value 1 and 2 and divide by 2.
- The result (mean value) must be 5 ± 0.25 mm.
If the result (mean value) is not 5 ± 0.25 mm:
-- Correct the adjustment, tighten the lock nut hand tight and repeat the measurement.
If the result (mean value) is 5 ± 0.25 mm:
-- Tighten the lock nut and secure it with sealing wax.
- Tightening specification: 5 Nm.
-- Secure the securing plate above the vacuum diaphragm linkage.
- Make sure the securing plate is locked in place.