ECT Sensor With A Retaining Plate
-- Disconnect the connector -2- from the ECT sensor.
-- Remove the bolts -arrows- and remove the retaining plate -1-.
-- Remove the ECT sensor.
NOTE:
Install the new ECT sensor with O-ring as quickly as possible to prevent coolant from leaking out.
Installing
Tightening specifications, refer to the following:
Install in reverse order of removal. When doing this note the following:
NOTE:
Replace the O-ring.
-- Clean the O-ring sealing surface.
-- Check the coolant level. Refer to DRAINING AND FILLING .