Round Connector Systems
Housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing the contacts, refer to SECONDARY LOCK .
-- Guide the release tool which fits the terminal housing into release channel on terminal housing.
-- Grasp contact at wire and push it gently into terminal housing -arrow-.
NOTE:
By pushing contact in direction of terminal housing, contact retaining tabs are lifted off the housing shoulder and can be released using the release tool.
-- At the same time, push release tool in direction of terminal housing -arrow- and pull the released contact out of terminal housing.
-- After removing the contact, release tool can be pulled out of terminal housing again.