LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 2009 >> GLI 2.0 J, Standard >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Wiring - General Information (Sedan) (A5 Platform) >> 97 Wiring >> Description And Operation >> Hot Air Blower Vas 1978/14

Hot Air Blower Vas 1978/14

Fig 1: Hot Air Gun (VAS1978/14)
GWWN97-10492Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
CAUTION:

When heat-shrinking crimp connections, be careful not to damage any other wiring, plastic parts or insulating material with the hot nozzle of the VAS 1978/14.

Always follow the operating instructions for the VAS 1978/14!

VAS 1978/14 is used in conjunction with Shrink Element For Hot Air Blower VAS 1978/15 to heat-shrink the crimp connections. After crimping, crimp connections must be heat-shrunk using the VAS 1978/14 to prevent moisture penetration.

The VAS 1978/14 is a component of Wiring Harness Repair SetVAS 1978/Wiring Harness Repair Set VAS 1978A/Wiring Harness Repair Set VAS 1978B.

Heat-shrinking crimp connections using VAS 1978/14, refer to WIRE BREAK WITH SINGLE REPAIR POINT , or WIRE BREAK WITH DUAL REPAIR POINT .