Charge Air Cooler
Removing
-- Bring the lock carrier into service position Description and Operation .
-- Remove the bolts -arrows-.
The air conditioning refrigerant circuit must not be opened.
-- Disconnect all the electrical connections, which lead to the lock carrier and the components on the lock carrier.
-- Pull the and support the condenser, charge air cooler and radiator with radiator fan off the lock carrier and support them.
-- Remove the bracket from the charge air cooler.
-- With a second technician, remove the guide pins T10093 from the longitudinal members and carefully remove the lock carrier -1-. While do this, make sure that all the connections are disconnected.
-- Remove bolts -arrows- from radiator.
-- Remove the radiator from the charge air cooler and support it.
To prevent damage to condenser and also to the refrigerant lines/hoses, ensure that the pipes and hoses are not stretched, kinked or bent.
-- Remove the bolts -arrows-.
-- Remove the condenser from the charge air cooler and support it.
-- Separate the condenser and the radiator from each other and remove the charge air cooler.
Installing
Installation is performed in reverse order. When doing this note the following:
-- With a second technician, install the lock carrier -1-. While doing this, install the guide pins T10093 into the longitudinal member.
Tightening Specifications
| Component | Nm |
|---|---|
| Condenser to charge air cooler | 5 |
| Radiator to charge air cooler | 5 |