Read Measuring Value Block
Special tools, testers and auxiliary items
- V.A.G 1551 Scan tool with V.A.G 1551/3 cable
- Connecting scan tool. Refer to Scan tool, connecting . Initiating On Board Diagnostic (OBD). Refer to Convenience system, initiating On Board Diagnostic (OBD) .
The measured values in the functions Read Measuring Value Block and basic setting are described during the individual component test. This table serves only as an overview.
The measured value block is divided into 10 display group numbers. The assignment of the individual display zones can be taken from the display group overview. Refer to Display group overview .
Indicated on display:
| Rapid data transfer HELP Select function XX |
- Press buttons -0- and -8- (08 initiates the "Read Measuring Value Block" function).
Indicated on display:
| Rapid data transfer Q 08 Read Measuring Value Block |
- Confirm entry with the -Q- button.
Indicated on display:
| Read Measuring Value Block HELP Input display group number XX |
NOTE:
The display group number 001 is an example, to illustrate the sequence.
- Press buttons -0-, -0- and -1- for "Display group number 1" and confirm entry with -Q- button.
Indicated on display: (1 to 4 = Display zones)
| Read Measuring Value Block 1 → 1 2 3 4 |
NOTE:
To change to another display group proceed as follows:
| Display group | V.A.G 1551 | V.A.G 1552 |
| Higher | Press button -3- | Press ↑ button |
| Lower | Press button -1- | Press ↓ button |
| Skip | Press button -C- | Press button -C- |
- Displayed after pressing -C- button.
Indicated on display:
| Read Measuring Value Block HELP Input display group number XXX |
- Now enter the display group number required.