Read Measuring Value Block: Notes
WARNING:
- Only visual check of wiring!
- Do not carry out electrical continuity tests or measurements to ignition circuits!
- Only check wiring with ignition switched off!
Indicated on display:
| Rapid data transfer HELP Select function XX |
- Press buttons -0- and -8- (08 initiates the "Read Measuring Value Block" function).
Indicated on display:
| Rapid data transfer Q 08 Read Measuring Value Block |
- Confirm entry with the -Q- button.
Indicated on display:
| Read Measuring Value Block HELP Input display group number XXX |
- Select relevant display group number and confirm entry with -Q- button.
Indicated on display: (1 to 4 = Display zones)
| Read Measuring Value Block 1 → 1 2 3 4 |
The explanation of the individual display zones on the display is found in the evaluation of display group numbers. Refer to Evaluation for display group number 001 .
NOTE:
Some of the indicated display groups are only meaningful for respective vehicle equipment (e.g. side airbag).
If the displayed values in all display zones are "correct":
- Press → button.
Indicated on display:
| Rapid data transfer HELP Select function XX |
NOTE:
Check DTC memory after completing the function "Read Measuring Value Block". Refer to Check DTC Memory
.