LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 2006 >> GTI 1.8 E, Automatic >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 18 (Wiring - General Information) >> 97 Wiring >> Removal And Installation >> Wire Break With Single Repair Point

Wire Break With Single Repair Point

WARNING: This page is about a different variant/trim than selected.

Repair point with single crimp connection

Fig 1: Identifying Single Repair Point
GWWN97-0010Courtesy of VOLKSWAGEN UNITED STATES, INC.

-- Free up wire intended for repair (approximately 20 cm to both sides of repair point).

-- If required, remove wiring harness wrapping using a folding knife.

-- Cut out the damaged wire section using wire stripper -VAS 1978/3-.

Fig 2: Identifying Wire Stripper To Cut Wire
GWWN97-0017Courtesy of VOLKSWAGEN UNITED STATES, INC.
NOTE:

If, by cutting out the damaged wire section, both ends of the vehicle-specific single wire are too short for a repair using a single crimp connection, insert a repair wire section of matching length with two crimp connections. Refer to WIRE BREAK WITH DUAL REPAIR POINT .

-- Strip wire ends using 6 - 7 mm wire stripper.

Fig 3: Identifying Stripping Pliers To Strip Wiring Insulation
GWWN97-0016Courtesy of VOLKSWAGEN UNITED STATES, INC.

-- Slide crimp connection onto both stripped wire ends of vehicle-specific single wire and crimp them using crimp pliers.

Fig 4: Identifying Crimping A Single Break Point
GWWN97-10490Courtesy of VOLKSWAGEN UNITED STATES, INC.
NOTE:

Always be sure to use the correct crimping slot for the crimping connection used. Refer to CRIMPING PLIERS WITH INSERT .

Do not crimp wire insulation.

After crimping, crimp connections must be heat-shrunk using hot air gun to prevent moisture penetration.

-- Put Shrink Tip For Hot Air Blower -VAS 1978/15- onto Hot Air Blower -VAS 1978/14-.

-- Heat crimp connection using hot air gun lengthwise from center outward until it is sealed completely and adhesive comes out the ends.

Fig 5: Identifying Heating Of Crimp Connection Using Hot Air Gun
GWWN97-0013Courtesy of VOLKSWAGEN UNITED STATES, INC.
CAUTION:

When heat-shrinking crimp connections, be careful not to damage any other wiring, plastic parts or insulating material with the hot nozzle of the hot air gun.

Always observe operating instructions of heat gun.

NOTE:

Make sure that crimp connections do not lie directly next to each other when several wires need to be repaired. Arrange the crimp connectors at a slight offset so that the circumference of the wiring harness does not become too large.

Fig 6: Identifying Offset Positions Of Crimped Connections
GWWN97-0011Courtesy of VOLKSWAGEN UNITED STATES, INC.

In the event the repair point was previous taped, this point must be taped anew with yellow insulating tape after repairs.

Secure the repaired wiring harness if necessary with a cable tie to prevent flapping noises while driving.