Turbocharger Vacuum Diaphragm, Adjusting
Special tools and workshop equipment required
- Pressure Control Valve VAS 6342
- Dial Gauge Set, 4 Part VAS 6341
- Hand Vacuum Pump VAS 6213
- Turbocharger Tester V.A.G 1397 A
- Dial Gauge Holder VW 387
This procedure adjusts the vacuum diaphragm. The values may differ when testing a vacuum diaphragm that has already been adjusted.
The vacuum diaphragm must be adjusted only if the linkage was loosened.
Adjustment is performed only with the turbocharger removed.
-- Disconnect the hose -arrow- from the vacuum diaphragm.
-- Loosen the clip above the linkage on the turbocharger.
-- Loosen the lock nut -2-.
-- Adjust the bypass flap -1- above the vacuum diaphragm linkage -arrow- so the bypass flap can still be turned by hand.
-- Tighten the lock nut by hand.
-- Connect the hand vacuum pump VAS 6213, turbocharger tester V.A.G 1397 A and the pressure control valve VAS 6342 to the connection as shown in the illustration.
-- Close the pressure control valve VAS 6342 using the lever -1-.
-- Set the slide ring -1- on the hand vacuum pump VAS 6213 to position -B- for "pressure".
-- Turn on the turbocharger tester V.A.G 1397 A and set the slide switch to position II.
-- Secure the dial gauge holder VW 387 onto the turbocharger -arrow-.
-- Secure the dial gauge 0-30 mm VAS 6341/1 with the dial gauge extension 30 mm VAS 6341/3 and the flat pickup VAS 6341/4 on the dial gauge holder VW 387.
-- Set the dial gauge 0-30 mm VAS 6341/1 to 0 bar with a 1 mm preload.
-- Rotate the indicator on the dial gauge 0-30 mm VAS 6341/1 to 0.
-- Check the dial indicator for ease of movement.
-- Operate the hand vacuum pump VAS 6213 until the turbocharger tester V.A.G 1397 A displays 350 +/-5 mbar.
-- The dial gauge must display 4.1 mm to 4.3 mm, otherwise rotate the linkage of the vacuum diaphragm until the value is displayed.
-- Tighten the lock nut by hand.
-- Repeat the measurement.
The mm specification apply to the value read out (includes the 1 mm preload).
-- Release the pressure via the pressure control valve VAS 6342 to 0 mbar.
-- Set the dial gauge 0-30 mm VAS 6341/1 to 0.
The following measurements must be performed in one sequence. In the meantime, the pressure must not dissipate to 0.
-- Operate the hand vacuum pump VAS 6213 until the turbocharger tester V.A.G 1397 A displays 350 +/-5 mbar.
-- Read and make a note of the value on the dial gauge 0-30 mmVAS 6341/1.
-- Operate the hand vacuum pump VAS 6213 until the turbocharger tester V.A.G 1397 A displays 650 to 700 mbar.
-- Release the pressure via the pressure control valve VAS 6342 to 350 +/- 5 mbar.
-- Read and make a note of the value on the dial gauge 0-30 mm VAS 6341/1.
-- Add values 1 and 2 and divide by 2.
-- The result (mean value) must be 5 +/- 0.25 mm.
-- If the result (mean value) is not 5 +/- 0.25 mm, correct the adjustment, tighten the lock nut by hand and repeat the measurement.
-- If the result (mean value) is 5 +/- 0.25 mm, tighten the lock nut to 5 Nm and secure it with sealing wax.
-- Secure the securing plate above the linkage of the vacuum diaphragm.