EVAP Canister Purge Regulator Valve N80, Checking
Special tools and workshop equipment required
- Multimeter.
- Wiring diagram.
Test requirements
- Fuse -SB38- OK.
- The ignition switched off.
Voltage for the Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80- is supplied by the Power Supply Relay (terminal 30, B+) -J317-.
Test procedure
-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK .
Start diagnosis
-- Disconnect the Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80- electrical harness connector.
Checking internal resistance
-- Using a Multimeter --, check the resistance between terminals 1 and 2 of the Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80-.
Specified value: 22, 0 to 30, 0 Ω.
If the specified value was not obtained:
-- Replace the Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80-.
If the specification is obtained:
Checking voltage supply
-- Using a Multimeter --, check the electrical harness connector terminal 1 to Ground (GND) for voltage.
-- Operate the starter briefly.
Specified value: battery voltage.
If the specified value was not obtained:
-- Check the wiring connection from the Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80- electrical harness connector terminal 1 to the Power Supply Relay (terminal 30, B+) -J317- terminal 87 for an open circuit a short circuit to Battery positive (+) or to Ground (GND).
-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.
-- If necessary, repair the wiring connection.
If the specified value was obtained:
Check Ground (GND) activation
If the manufacturers test box is being used. Perform the following step.
-- Install the test box.
If the manufacturers test box is not being used. Perform the following step.
-- Remove the Engine Control Module (ECM) -J623-. Refer to ENGINE CONTROL MODULE J623, REPLACING .
-- Using a Multimeter --, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80- electrical connector terminal 2 to the Engine Control Module (ECM) -J623- electrical harness connector T121 terminal 64 for resistance.
| Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80- Electrical harness connector terminal | Engine Control Module (ECM) -J623- Electrical harness connector terminal or test box socket |
|---|---|
| 2 | 64 |
Specified value: 1.5 Ω.
If the specification was not obtained:
-- Check the wiring for an open circuit, a short circuit to Battery positive (+) or to Ground (GND).
-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.
-- If necessary, repair the wiring connection.
If the specification was obtained:
-- Erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
-- Perform a road test to verify repair.
If the DTC does not return:
Repair complete, Generate readiness code. Refer to READINESS CODE DESCRIPTION .
-- End diagnosis.
If the DTC returns and no malfunction is found in the wiring and voltage supply was OK:
-- Replace the Engine Control Module (ECM) -J623-. Refer to ENGINE CONTROL MODULE J623, REPLACING .
-- Assembly is performed in the reverse of the removal.
Final procedures
After repair work, the following work steps must be performed in the following sequence:
- Check the DTC memory. Refer to DIAGNOSTIC MODE 03 - READ DTC MEMORY .
- If necessary, erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
- If the DTC memory was erased, generate readiness code. Refer to READINESS CODE .
End of diagnosis