Home >> Volkswagen >> 2006 >> GTI 1.8 E, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 107 (1.8L - Fuel Injection Ignition, Engine Code(S): AWW, AWP (A4 Platform)) >> 01 On Board Diagnostic (OBD) >> Measuring Value Block >> Measuring value blocks, evaluating display groups 0 to 9 (Basic functions) >> Display group 4 (Basic functions)

Display group 4 (Basic functions)

WARNING: This page does not describe the selected car, but rather 13 other vehicles, including the 2005 Volkswagen Jetta, 2005 Volkswagen GTI, 2004 Volkswagen Jetta, 2004 Volkswagen GTI, and 2003 Volkswagen Jetta. However, it is still accessible from the selected car via links, so may be relevant.
Display group 4 (Basic functions)
  • Engine running at idling speed
Read Measuring Value Block 4 Indicated on display    
xxxx RPM xx.xxx V xxx.x ° C xxx.x ° C      
1 2 3 4 Display zones Specification Evaluation
        Intake air temperature -48 to 110 ° C Evaluating display group 4, display zone 4 - Intake air temperature  
      Coolant temperature 60 to 110 ° C Evaluating display group 4, display zone 3 - Coolant temperature  
    Voltage supply for engine control module 12.0 to 15.0 V Evaluating display group 4, display zone 2 - Control module voltage supply  
  Engine speed (idling speed): Manual transmission Automatic transmission 700 to 820 RPM 640 to 760 RPM Evaluating display group 1, display zone 1 - Engine speed (idling speed)  
NOTE:
  • For display zone 3:
  • The engine control module will use the intake air temperature as a replacement value for an engine start (start temperature - replacement value) as soon as there is a malfunction stored in the DTC memory, which affects the Engine Coolant Temperature (ECT) Sensor G62. The temperature then rises according to a model stored in the control module. When the engine has reached normal working temperature a fixed replacement value will be displayed after a certain period. This fixed value is also dependent upon the intake air temperature.
NOTE:
  • For display zone 4:
  • The total temperature range is given as the specification. The displayed value must be above ambient temperature.