Compressor shut-off, checking
WARNING: This page is about a different variant/trim than selected.
The A/C control head signals the Diesel Direct Fuel Injection Engine Control Module J248 that the A/C compressor will be switch on, via the A/C compressor signal.
Through another wiring connection, the engine control has the possibility of switching off the air conditioner compressor for various operating conditions:
- Hard acceleration from low speed
- Emergency program (emergency running operation)
- Coolant temperatures above + 120 ° C (248 ° F)