Work sequence
WARNING: This page is about a different variant/trim than selected.
- With engine at idle connect Scan Tool (ST) VAG1551 / VAG1552 and select Engine Control Module (ECM) with "Address word" 01. → Scan Tool VAS5051 , connecting , Scan Tool VAG1551 , connecting.
Indicated on display:
| Rapid data transfer HELP Select function XX |
- Press buttons 0 and 8 for "Read Measured value block" and confirm with Q button.
Indicated on display:
| Read measured value block Enter display group number XXX |
NOTE:
- The display group number - 001 - is an example, to illustrate sequence.
- Press keys 0 , 0 and 1 for "Display group number -1-" and confirm entry with Q key.
Indicated on display: (1...4 = Display zones)
| Read measured value block 1 → 1 2 3 4 |
- Press → button.
Indicated on display:
| Rapid data transfer HELP Select function XX |
- Press keys 0 and 6 for the "End output" function and confirm input with the Q key.
NOTE:
- To change to another display group proceed as follows:
| Display group | VAG1551 | VAG1552 |
| Higher | Press button 3 | Press ↑ button |
| Lower | Press button 1 | Press ↓ button |
| Skip | Press button C | Press button C |