Unit injector, servicing
WARNING: This page is about a different variant/trim than selected.
- Observe rules for cleanliness. Refer to Rules for cleanliness
- Always replace seals and O-rings
1 - 20 Nm plus an additional 14 turn (90 ° )
- Replace
- Note sequence when loosening and tightening. Refer to Unit injector, removing and installing , Unit injector, removing and installing
2 - Rocker arm shaft
- With rocker arm
- Removing and installing. Refer to Unit injector, removing and installing , Unit injector, removing and installing
3 - Lock nut, 30 Nm
4 - Adjustment screw
- Replace if there are signs of wear when installing a new unit injector
- Adjusting, refer to Unit injector, removing and installing , Unit injector, removing and installing
5 - Unit injector
- Check ball pin for signs of wear, replace if necessary
- Removing and installing. Refer to Unit injector, removing and installing
6 - O-ring
- Replacing, refer to O-rings for unit injector, removing and installing
7 - O-ring
- Replacing, refer to O-rings for unit injector, removing and installing
8 - O-ring
- Replacing, refer to O-rings for unit injector, removing and installing
9 - Heat insulation seal
- Replace
10 - Circlip
11 - Cylinder head
12 - Tensioning block
13 - 12 Nm plus an additional 34 turn (270 ° )
- Replace