LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 2004 >> GTI VR6 >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 14 (1.8L - Fuel Injection Ignition, Engine Code(S): AWW, AWP (A4 Platform)) >> 01 On Board Diagnostic (OBD) >> Output Diagnostic Test Mode >> Output Diagnostic Test Mode (function 03), performing >> Test conditions

Test conditions

WARNING: This page is about a different variant/trim than selected.
Fig 1: Identifying Main Fuse Panel
GW00000097Courtesy of VOLKSWAGEN UNITED STATES, INC.
NOTE:
  • The Output Diagnostic Test Mode can only be carried out if the engine is stationary and ignition switched on.
  • The Output Diagnostic Test Mode will be broken off if the engine is started or a rotational impulse is recognized.
  • During the Output Diagnostic Test Mode the individual final controls will be activated until advancing to the next final control by pressing the → button.
  • The final controls are checked acoustically or by touching.
  • If it is necessary to repeat the Output Diagnostic Test Mode, without first running the engine briefly, switch the ignition off for approx. 2 seconds.
  • The electric fuel pump will run during the complete Output Diagnostic Test Mode.