Combi-valve, checking
WARNING: This page is about a different variant/trim than selected.
Special tools, testers and auxiliary items required
- Hand vacuum pump V.A.G 1390
Test conditions
- There must be no malfunctions stored in DTC memory
- Output diagnostic test performed
- Vacuum lines and hose connections free of leaks
- Vacuum lines not blocked or kinked
Test sequence
- Remove vacuum hose - 1 - on Secondary Air Injection (AIR) Solenoid Valve N112 - 2 -.
- Connect Hand Vacuum Pump V.A.G 1390 to vacuum hose - 1 -.
NOTE:
- Do not use compressed air during following check!
- Disconnect pressure hose - 3 - at Secondary Air Injection (AIR) pump motor V101 and blow air in with light pressure - arrow -. Combination valve must be closed.
NOTE:
- To disengage, compress the buttons at the hose coupling.
- Operate Hand vacuum pump V.A.G 1390. Valve must open.
If combi-valve does not open:
- Replace combination valve.