EVAP system, checking using tester KILL 9210: Introduction
WARNING: This page is about a different variant/trim than selected.
The KLI90210 EVAP tester allows testing using nitrogen to pressurize the EVAP system and a smoke generator or ultrasonic tester to locate the source of EVAP system concerns.
This procedure is intended as a general guide for the use of the EVAP tester. EVAP systems vary between models.
Special tools, testers and auxiliary items required
- VAS 5051 or VAS 5052 diagnostic tester
- KLI90210 EVAP system tester (set to 14 in. H 2 O)
- Light source (for viewing smoke)
- Hose Clamps up to 25mm dia. 3094 or equivalent
Using the KLI90210 EVAP system tester, refer to Tester operating instructions