Test sequence
NOTE:
The deceleration shut-off valve is located in front of the turbocharger. It is opened by vacuum during deceleration and at idle.
- Connect hand vacuum pump (VAG1390) to vacuum connection for deceleration shut-off valve.
- Operate vacuum pump.
Deceleration shut-off valve must open in direction of arrow.
- Operate ventilation valve at vacuum pump.
Deceleration shut-off valve must close
If deceleration shut -off valve does not open or does not close, replace valve, see COMPONENTS OF CHARGE AIR COOLER, REMOVING AND INSTALLING .
NOTE:
Secure connections of deceleration valve using screw-type clamps.