Home >> Volkswagen >> 2001 >> Jetta GL, 2.0 S, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 42 (4 SPD. Automatic Transmission 01M (A4 Platform)) >> 38 Automatic Transmission - Gears, Hydraulic controls >> Solenoid Valves in Valve Body, Checking >> Checking resistance

Checking resistance

WARNING: This page is about a different variant/trim than selected.
Solenoid Valve Electrical Harness Connector Terminal Specified Value (Approx. 20 ° C)
Solenoid Valve 1 N88 1 to Ground (GND) 10.0 - 16.0 Ω
Solenoid Valve 2 N89 2 to Ground (GND) 10.0 - 16.0 Ω
Solenoid Valve 3 N90 7 to 8 4.0 - 8.0 Ω
Solenoid Valve 4 N91 11 to 12 4.0 - 8.0 Ω
Solenoid Valve 5 N92 3 to 4 4.0 - 8.0 Ω
Solenoid Valve 6 N93 13 to 14 4.0 - 8.0 Ω
Solenoid Valve 7 N94 5 to 6 4.0 - 8.0 Ω

If the specification was not obtained:

If the specified values are obtained: