Measured value block, reading: Notes
WARNING: This page is about a different variant/trim than selected.
Additional information
- Electrical Wiring Diagrams, Troubleshooting and Component Locations
- Connect VAG 1551 Scan Tool and enter address word "02 Transmission electronics". Advance until "Select function XX" is indicated on display. Refer to VAG 1551 Scan Tool, connecting and selecting functions .
Indicated on display
| Rapid data transfer HELP Select function XX |
- Press buttons -0- and -8- to select "Read measured value block" function 08.
Indicated on display
| Rapid data transfer Q 08 - Read measured value block |
- Confirm entry with -Q- button.
Indicated on display
| Read measured value block Enter display group number XXX |
- Enter display group number. Refer to List of selectable display group numbers. See List of selectable display group numbers .
- Confirm entry with -Q- button.
There are always 4 display fields in the measured value block (in actual physical quantities if necessary). Decoding the individual values in display fields 1 to 4. Refer Test table .
| Read measured value block 1 → → 1 → 2 → 3 → 4 |