Fuel Pump (FP) check-valve, checking
WARNING: This page is about a different variant/trim than selected.
Test conditions
- Remote control V.A.G 1348/3A connected
- Fuel Inj. Pressure Gauge V.A.G 1318 is still connected.
Test sequence
NOTE:
- This test also checks the connections of the fuel supply line from fuel delivery unit to connection point of pressure gauge V.A.G 1318 for proper seal.
- Close pressure gauge V.A.G 1318 shut-off tap (lever at right angle to direction of flow position - B - ).
- Operate remote control at short intervals, until a pressure of approx. 3 bar has built up.
CAUTION:
Danger of spraying when opening shut-off valve; wear protective goggles and protective clothing to prevent injuries and contact with skin. Hold container in front of free connection of pressure measuring device V.A.G 1318.
- If pressure builds up too high, lower excess pressure by carefully opening shut-off tap.
- Watch pressure drop on gauge. After 10 minutes the pressure must not drop below a 2.5 bar decrease.
If pressure drops further:
- Check line connections for leaks.
If no fault is detected in wiring:
- Fuel Pump (FP) faulty, replace fuel delivery unit refer to Fuel delivery unit, removing and installing .
- Check DTC memory.
- Read readiness code.
- If DTC memory was cleared or engine control module disconnected from voltage supply, readiness code must be regenerated.