Testing the fuel cap
WARNING: This page is about a different variant/trim than selected.
- Remove fuel cap.
- Connect fuel cap receiver (arrow) to hose.
- Screw fuel cap tightly to cap receiver.
- Turn control valve to "Test" pressurizing cap.
- Turn valve to "Hold".
- Watch pressure gauge for drop in pressure from 14 inches H 2 O.
If no pressure drop is indicated:
- Proceed to checking Leak Detection Pump (LDP) V144 for internal leaks.
If pressure drop is indicated:
- Replace fuel cap and re-test.