Checking resistance of solenoid valves
WARNING: This page is about a different variant/trim than selected.
- Measure resistance of solenoid valves at test box between socket of corresponding solenoid valve to socket 1 according to wiring diagram:
| Component | Specified value Ω |
| Solenoid Valve 1 -N88- | 9.0 to 24.0 |
| Solenoid Valve 2 -N89- | 9.0 to 24.0 |
| Solenoid Valve 3 -N90- | 9.0 to 24.0 |
| Solenoid Valve 4 -N91- | 9.0 to 24.0 |
| Solenoid Valve 5 -N92- | 9.0 to 24.0 |
| Solenoid Valve 6 -N93- | 1.0 to 5.0 |
| Solenoid Valve 8 -N281- | 9.0 to 24.0 |
| Solenoid Valve 9 -N282- | 9.0 to 24.0 |
| Solenoid Valve 10 -N283- | 1.0 to 5.0 |
NOTE:
Resistance value is valid at approx. 20 ° C. At higher temperatures, resistance value increases.
If one of the specified values is not obtained:
- Check wires to Transmission Control Module (TCM) according to wiring diagram. Refer to Checking wires to Transmission Control Module (TCM) .