Checking resistance of solenoid valves
WARNING: This page is about a different variant/trim than selected.
- Re-connect 12-pin connector.
- Connect test box to control module wiring harness. Refer to Test box, connecting for wiring test
- Measure resistance of solenoid valves at test box between sockets:
| Component | Sockets | Specified value Ω |
| Solenoid Valve 1 -N88- | 55+67 | 55.0 to 65.0 |
| Solenoid Valve 2 -N89- | 54+67 | 55.0 to 65.0 |
| Solenoid Valve 3 -N90- | 9+67 | 55.0 to 65.0 |
| Solenoid Valve 4 -N91- | 47+67 | 4.5 to 6.5 |
| Solenoid Valve 5 -N92- | 56+67 | 55.0 to 65.0 |
| Solenoid Valve 6 -N93- | 22+58 | 4.5 to 6.5 |
| Solenoid Valve 7 -N94- | 10+67 | 55.0 to 65.0 |
NOTE:
Resistance value is valid at approx. 20 ° C. At higher temperatures, resistance value increases.
If one of the specified values is not obtained:
- Check wires to Transmission Control Module (TCM) according to wiring diagram. Refer to Checking wires to Transmission Control Module (TCM) .