Home >> Volkswagen >> 2001 >> Jetta GL, 2.0 S, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 77 (2.8L - Engine Mechanical, Engine Code: BDF) >> 20 - Fuel Supply >> Components of fuel supply system, servicing >> Fuel pump, checking >> Checking delivery rate >> Test sequence

Test sequence

WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2005 Volkswagen GTI, 2004 Volkswagen Jetta, 2004 Volkswagen GTI, 2003 Volkswagen Jetta, and 2003 Volkswagen GTI. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying Vacuum Hose To Throttle Valve Control Module, Fuel Return Hose & Fuel Supply Hose
GW00000005Courtesy of VOLKSWAGEN UNITED STATES, INC.
NOTE:
  • Press buttons on hose couplings to do so.
CAUTION: Fuel supply lines are under pressure! Before removing from hose connections wrap a cloth around the connection. Then release pressure by carefully pulling hose off connection.
Fig 2: Connecting VAG 1318 Components To Fuel Supply Line
GW00000196Courtesy of VOLKSWAGEN UNITED STATES, INC.

The quantity of fuel delivered by the fuel pump depends on the battery voltage.

Fig 3: Fuel Delivery Rate Graph
GW00000197Courtesy of VOLKSWAGEN UNITED STATES, INC.

* Minimum delivery cm 3 /30 seconds

* Voltage at fuel pump with engine not running and pump running (approx. 2 volts less than battery voltage).

Example:

During the test, a voltage of 12.2 volts is measured at the battery. As the voltage at the pump is approx. 2 volts less than the battery voltage, the result is a minimum delivery of 200 cm 3 /30 seconds.

If the minimum delivery rate is not attained:

Fig 4: Connecting Pressure Gauge VAG 1318 To Hose With Adapter VAG 1318/17 To Fuel Filter
GW00000198Courtesy of VOLKSWAGEN UNITED STATES, INC.
NOTE:
  • Press buttons on hose couplings to disconnect.

If the minimum delivery rate is now attained:

If the minimum delivery rate is again not attained:

Only if no faults have been detected up to now:

If the delivery rate has been attained but a fuel supply system fault is still suspected (e.g. intermittent failure of fuel supply system):

Fig 5: Measuring Current Draw Of Fuel Pump Using VAG 1715
GW00000199Courtesy of VOLKSWAGEN UNITED STATES, INC.
NOTE:
  • If the fuel system malfunction is intermittent, perform the check during a test drive with the assistance of a 2nd person.

If the current draw is exceeded: