Combi-valve, checking
WARNING: This page is about a different car, the 2004 Volkswagen R32. However, it is still accessible from the selected car via links, so may be relevant.
Special tools, testers and auxiliary items required
- Hand vacuum pump VAS 6213
Test conditions
- Vacuum lines and hose connections free of leaks
- Vacuum lines not blocked or kinked
Test sequence
- Pull off vacuum hose at combi-valve - 1 -.
- Connect hand vacuum pump VAS 6213 to vacuum hose from combi-valve - 1 -.
NOTE:
- Do not use compressed air during following check!
- Detach pressure hose to combi-valve at connection - arrow - and pressurize slightly by blowing into hose. Combi-valve must be closed.
- Operate Hand vacuum pump VAS 6213. Combi-valve must open.
If combi-valve does not open:
Replace combi-valve.