Checking resistance
WARNING: This page is about a different variant/trim than selected.
- Using a multimeter , check the Solenoid Valve terminals 1 to 2 at the Solenoid Valve electrical harness connector for resistance.
| Solenoid Valve | Electrical Harness Connector Terminal | Specified Value (Approx. 20 ° C) |
|---|---|---|
| Solenoid Valve 1 N88 | 1 to Ground (GND) | 10.0 - 16.0 Ω |
| Solenoid Valve 2 N89 | 2 to Ground (GND) | 10.0 - 16.0 Ω |
| Solenoid Valve 3 N90 | 7 to 8 | 4.0 - 8.0 Ω |
| Solenoid Valve 4 N91 | 11 to 12 | 4.0 - 8.0 Ω |
| Solenoid Valve 5 N92 | 3 to 4 | 4.0 - 8.0 Ω |
| Solenoid Valve 6 N93 | 13 to 14 | 4.0 - 8.0 Ω |
| Solenoid Valve 7 N94 | 5 to 6 | 4.0 - 8.0 Ω |
If the specification was not obtained:
- Replace the faulty Solenoid Valve . Refer to Automatic Transmission - Repair Group 37.
If the specified values are obtained: